TS8500S технические характеристики.
Moдель | TS8500S (LED, без дисплея) |
Optical Geometry | Reflect: D/8 (diffused illumination, 8-degree viewing angle) ; |
SCI/SCE; Include UV / excluded UV light source ; | |
Transmittance: D/0 (diffuse illumination: 0° viewing) ; | |
SCI /SCE; Include UV / excluded UV light source ; | |
HAZE (ASTM D1003); | |
Standards meet: CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724/1,ASTM E1164,DIN5033 Teil7,JIS Z8722 under condition C | |
Characteristic | 1. Widely applied in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
2. Instrument can be measured on the side, upward measurement, and the downward measurement (use accessories) and other gestures. | |
3. Open transmission warehouse, available thickness of 54mm transmitted samples. | |
4. Automatic temperature and humidity compensation function. | |
Integrating Sphere Size | Φ154mm |
Light Source Device | 360nm–780nm Wavelength range ,combined LED Light. Including UV, 400nm cut-off light source, 420nm Cut-off light source,460nm cut-off light source |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360~780nm |
Wavelength Interval | 10nm |
Semiband Width | 5nm |
Measured Reflectance Range | 0~200% |
Reflectivity Resolution | 0.01 |
Measuring Aperture | Reflective: |
XLAV Φ25.4mm/Φ30mm, LAVΦ15mm/Φ18mm , MAVΦ8mm/Φ10mm, SAVΦ4mm/Φ6mm |
|
Transmissive: | |
Φ25.4mm(No limit on sample height and width, but thickness≤54mm) | |
Remark: | |
1. Automatic identification of aperture switch | |
2. Customized Configuration caliber and lens position | |
Specular Component | Reflectance: SCI&SCE / Transmittance: SCI&SCE |
Color Space | CIE LAB,XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB, HunterLab, βxy, DIN Lab99 |
Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter),ΔE*CH,555 Index |
Other Colorimetric Index | WI(ASTM E313,CIE/ISO,AATCC,Hunter,Taube,Berger Stensby) |
YI(ASTM D1925,ASTM 313),ISO brightness,R457 | |
MI (Metamerism Index), | |
Staining Fastness, Color Fastness, Color Strength, Opacity, | |
APHA/Hazen/Pt-Co Index,Gardner Index | |
8° Gloss,555 Index, Haze,Transmission(ASTM D1003),Saybolt index, ASTM D1500 Color code,carbon(My,dM),Color density CMYK(A,T,E,M),Tint,Color density(part function achieved via software in PC) | |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30,B,U35,NBF |
ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-C2,LED-C3,LED-C5, customized light source(41 light sources in total,part achieved via software in PC) | |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset, Color assessment, haze, liquid chromaticity |
Measuring Time | 2.0s (Measure SCI & SCE meantime about 4s ) |
Repeatability | Reflectance chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 ( Under LED light source, when a white calibration plate is measured 30 times at 5 second intervals after white calibration); |
spectrum reflectance /transmission:≤0.1% | |
Inter-instrument Error |
Φ25.4mm/SCI, Within ΔE*ab 0.15 (Average for 12 BCRA Series II color tiles) |
Dimension | L*W*H=440x248x283mm |
Weight | Approx. 13.5kg |
Power | AC 24V, 3A Power adapter power supply |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display | No |
Data Port | USB & Bluetooth 5.0 |
Data Storage | Share with PC storage |
Language | / |
Operating Environment | 0~40℃(32~104°F) |
Storage Environment | -20~50℃(-4~122°F) |
Standard Accessory | Power Adapter, User Guide, U Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber,Transmissive Test Component, cuvette |
Optional Accessory | Micro Aperture(4mm) transmission test clamp component, Instrument inversion components,culture dish,Film fixture |
Notes |
Test reports can be printed through a network printer connected to a PC or display pad, The specifications are subject to change without notice. |